Cxx-58 Encoder
Interface: EtherNet/IP
EDS file: 04710022_TR_C_SERIES_x_x.eds

*************************************************************************************************************

EDS file: 04710022_TR_C_SERIES_x_x_Omron.eds
Specific for Omron Controls.
The attributes "19, Preset Value" and "104, Preset Value Extended" are set to "Read Only"
Reason: In this case it isn't possible to execute the Preset-function when the control is in the start-up phase.

*************************************************************************************************************

EDS file: 04710022_TR_C_SERIES_x_x_Schneider.eds
Specific for Schneider Controls.
The data type "ENGUNIT" is not supported, for the attributes
- "15, Position Format"
- "25, Velocity Format"
- "107, Temperature Value Format"
therefore the data type "UINT" is declared.

Further the data type "ULINT" (8-Byte) is not supported.
For the attributes
- "100, Position Value Extended"
- "101, Total Measuring Range"
- "104, Preset Value Extended"
therefore the data type "UDINT" (4-Byte) is declared. Thus, these attributes cannot be used!

*************************************************************************************************************

DOCUMENTATION:

TR-ECE-BA-DGB-0102 (german/english)